|     
Problem 
 |        
Solution 
 |   
   |     
Installation 
 |   
   |     
While installing error- 
“Insert Disk” 
 |        
There is an old speednet CAB file present in OS installation   folder. 
Please search for sp*.cab file in C:\Windows or C:\Winnt   folder. If found delete them. 
Then install the package afresh 
 |   
   |     
While installing system is asked to be restarted every time. 
 |        
Check whether Service Pack SP 4 for Windows 2000 or SP3 for XP   systems are installed. 
 
 |   
   |     
While installing – error MSDART.dll file 
 |        
If the following error occurs during the Client installation – 
“The Procedure entry point couldn’t be located in the dynamic   link library MSDART.DLL.” 
When the error occurs – Click on OK. 
Then next it will show a file registration error – Click on   Ignore. 
Then again the MSDART.DLL error occurs . Click on OK 
Then next it will show another file registration error – Click   on 
Ignore 
Now it will install. 
Now package gets installed. This error will not cause any   problem in the package. 
Note: If any Version Conflict messages   appears, then keep the existing files in the system and continue the   installation. 
 |   
   |     
At the end of the installation error – “Path not Found” 
 |        
Click on Retry button to continue. If this doesn’t solve the   problem, reinstall the client component. 
 |   
   |     
Active X Component Error – 
Found at any stage during installation. 
 |        
Check whether Service Pack SP 4 for Windows 2000 or SP3 for XP   systems are installed. Also install MDAC 2.7 
If using Speednet 3.1 then download the 3.1.1 version from   site. 
 |   
   |     
Installation problem in Vista System for the first time 
 |        
Right click on the setup.exe file and select option.   This will install the package without any problem. 
Also register all the dll files which are in the SpeedNet   Client Installation folder. 
To register the dll: 
· Right click on   Dll file and select Open with 
· Select Browse   option and go to Windows\System 32 folder. Select Regsvr32 file 
· Select open   and ok button in the subsequent forms. 
· This will show   the successful registration message. 
· If
 this   process is not registering the Dll then :- please uninstall the 
SpeedNet   client and ensure that old installation files doesn’t exist 
in the system.   Then go to start->Run and type msconfig. A System 
Tools window opens.   Click on Tools option. Search for option
   from the list. Select it and click on Launch. Restart the system then
 install   the SpeedNet client and then register the Dlls. At the end 
don’t forget to go   to msconfig ->Tools and select and   launch and restart system. 
Note: Enable User Account Control is a must as it is a new   security component in Windows Vista. 
 |   
   |     
 
 
 |        
 
 
 |   
   |     
Configuration – Database Creation 
 |   
   |     
While creating the database, message appears as – “Unable to   load the configuration file” 
 |        
Uninstall the SpeedNet Client component from Control Panel   –Add Remove Programs and reinstall it. 
 |   
   |     
While creating the database, “Speed Net found an illegal   tampering of information... Quitting” 
 |        
Uninstall the SpeedNet Client component from Control Panel   –Add Remove Programs and reinstall it. 
 |   
   |     
While creating database error – 
“SQL Server error. Please close all applications” 
 |        
This is the error related to Hard disk. Check the following. 
· Drive letter   provided is wrong 
· POSPCC and   POSPCCBackup files exist in hard disk 
· No space in   the hard disk. 
 |   
   |     
While creating the database error – “Specified SQL Server not   found” 
 |        
The
 Server name provided is wrong. Please also check whether   you have 
installed SQL as Instance. If so, edit the SQL Server name with SQL   
Instance name. 
 |   
   |     
While creating the database error “Login failed for user SA” 
 |        
The SQL Password typed is wrong. 
 |   
   |     
In vista – shared file is not being accessed at the end of   client installation. 
 |        
In
 cases where new systems are supplied to project arrow   offices, some 
problems in accessing server component folder even after   sharing this 
folder may occur due to architecture of new OS installed in   these 
systems. 
IN such case system administrator should overwrite defaults   permissions given to SpeedNet server folder : 
To do this they can follow the procedure below: 
If it is vista operating system do the following steps before configuring the permissions: 
1. Go to Start->Run and type msconfig 
2. Under Tools, select Disable UAC and click on Launch button   given below. 
3. Restart the system. 
4. Applying the permission changes to SpeedNet server folder   as given below. 
Permissions: 
7) Right click SpeedNet Server folder, select Properties   ->Security tab and click on button   therein. 
2) Select the user if   already present in the list there or Click on Edit and then button. Type everyone and click   on OK. 
3) In the next screen, check on   permission for Allow. 
4) Click on advanced 
5) Uncheck the check box .   A new option screen appears wherein click on remove button 
6) Now click on OK button and Ok button in the previous screen. 
7) Share the SpeedNet server folder and assign full permission   to user 
on shared folder. 
Give similar permissions to user as above. 
 |   
   |     
 
 
 |        
 
 
 |   
   |     
Configuration – Other Issues 
 |   
   |     
While configuring, the required SPC name is not found for   selection. Then how to install? 
 |        
The
 procedure is explained in the SpeedNet Hand Book supplied   along with 
3.1 version release and the copy of the same is available in   Speednet 
3.1 CD. (Refer 2.8) 
 |   
   |     
Error Inserting Offices to OfficeMaster –Could not bulk   insert. File ‘SPCMaster.txt’ does not exist 
 |        
This problem is solved in Speednet 3.1.1. 
You are using older version. Please download the 3.1.1 version   and upgrade. 
 |   
   |     
While configuring at linked office, Linked office name not   found for selection. How to install? 
 |        
The
 procedure is explained in the SpeedNet Hand Book supplied   along with 
3.1 version release and the copy of the same is available in   Speednet 
3.1 CD. (Refer 2.9) 
 |   
   |     
“Automation Error” at the time of configuration 
 |        
Solution 1: 
Dll
 Registry problem. Please open the Speednet client folder   path 
(C:\Program Files\Speednet default folder) . Register all the dll files 
  using the regsvr32 file. 
Procedure to register: 
1. Right click   on The dll file 
2. Click on –   Open with option 
3. Browse –   C:\Windows\System32 
4. Select the   file regsvr32.dll 
5. Click on Ok   to register. 
If it is Vista System and there is problem in registration of   Dll files, please see the solution given at the heading – as to how to   register the dll files in vista. 
 |   
   |     
While configuring Error - 
"Text property read only" 
 |        
This is the problem with old cab file remaining in the system   during fresh installation of SpeedNet 3.1.1 
Uninstall Speednet client from Add Remove programs 
Search for C:\Program Files\Speednet folder ( Its default path   of client folder) . If exists delete it. 
Now
 go to search option ( or Find) of windows and search for   spcl*.cab 
file in C:\Windows folder. If any such file exists delete it. 
Then install the Speednet Client 3.1.1 afresh. 
 |   
   |     
Login 
 |   
   |     
While starting the package itself, there is error 
“Error in Opening the Connection 70. Permission denied” 
 |        
This problem would have occurred in Vista   systems. 
As a solution, right click on the SpeedNet exe and click on   Run As Administrator option and click on Allow to run the package. 
 |   
   |     
While logging in it says the user is already logged in other   system. 
 |        
This problem is solved in Speednet 3.1.1. 
You are using older version. Please download the 3.1.1 version   and upgrade. 
 |   
   |     
Error while logging in – 
“Not a valid Password” 
 |        
This is mdb file access error through the client system. 
Check
 the sharing permissions of the SpednetServer folder at   server system.
 Whether the XP client user has been given full permission to   access 
the folder. 
If
 by giving permission if the problem is not solved, then   reinstall the
 SpeedNet Server component and share it afresh with full   permission to 
(BNPL Module – old bill data will be lost with the re   installation of SpeedNet Server) 
 |   
   |     
Error while login – 
“BNPL Database is not found in the specified path” 
 |        
This problem is solved in Speednet 3.1.1. 
You are using older version. Please download the 3.1.1 version   and upgrade. 
 |   
   |     
Login is very slow and takes too much time. 
 |        
Login
 as Supervisor – Use Tools->Delete Old data option.   Use Truncate 
option to truncate the log files of POSPCC and POSPCCBackup.   (Please 
ensure that no one uses SpeedNet at that time, else DB will be   
corrupt) 
 |   
   |     
While
 Logging in Vista Systems, when selected user, given   password and 
click on OK, package simply exists without any message or error 
 |        
Right
 Click on the Speednet.exe which is in the SpeedNet   client path 
(default client path is C:\Program Files\SpeedNet) and click on. 
If
 this is not working then please share the SpeedNet Server   folder in 
the Server System with Special Permission as given in the   instruction 
at the heading 
 |   
   |     
Shift Begin /Shift End 
 |        
 
 
 |   
   |     
While making Shift End error – it gives 
BNPL Error / 
Pending Message error 
 |        
This problem is solved in Speednet 3.1.1. 
You are using older version. Please download the 3.1.1 version   and upgrade. 
 |   
   |     
While making the Shift Begin – it shows the error that system   date and time is incorrect. 
 |        
Please check whether the System date is Current Date. 
From
 SpeedNet 3.1 onwards , package will not allow to make the   Shift Begin
 for a date for which already Shift Begin and Shift End are done. 
 |   
   |     
While making shift End – it shows a big list of non dispatched   bags. 
 |        
This is not an error. 
Please read the SpeedNet User Manual or for details on Non   Dispatched Bag List. 
 |   
   |     
While making the Shift End – Package exists automatically 
 |        
Please
 read the SpeedNet User Manual for details on Shift End   for Non 
Dispatched Bag List. If the list contains huge number of pending bags   
due to incomplete work in the package, then this happens. 
Reinstallation is the solution. 
 |   
 
0 comments:
Post a Comment